| Nome: | Descrição: | Tamanho: | Formato: | |
|---|---|---|---|---|
| 264.36 KB | Adobe PDF |
Orientador(es)
Resumo(s)
Introduction: Contrast rapid sequence angiography with fluorescein or indocyanine green (ICG) is a diagnostic procedure commonly used in ophthalmology. Adverse reactions to fluorescein and ICG are rare and may be classified as toxic, of hypersensitivity and non-specific. The evaluation and management of a patient with an adverse reaction is a challenge for the majority of ophthalmologists, as is the assessment of risk factors that may contraindicate the procedure.
Purpose: We aim to review the concepts underlying adverse reactions to fluorescein and ICG, especially those of hypersensitivity, and present a proposal or the evaluation of the patients in need to perform retinal angiography and for the treatment of immediate reactions to fluorescein and ICG.
Methods: The available literature was examined using PubMed-Medline, and using the MeSH terms "fluorescein", "Indocyanine green", "ophthalmic dyes", "retinal angiography", "adverse reactions", and "allergic reaction".
Conclusion: This review may help ophthalmologists to identify patients with higher risk of a hypersensitivity reaction and give them tools to recognize patients with suspected hypersensitivity that may benefit from an allergy study.
Descrição
Palavras-chave
adverse reactions fluorescein hypersensitivity reaction indocyanine green ophthalmic dyes retinal angiography
Contexto Educativo
Citação
Meira J, Marques ML, Falcão-Reis F, Rebelo Gomes E, Carneiro Â. Immediate Reactions to Fluorescein and Indocyanine Green in Retinal Angiography: Review of Literature and Proposal for Patient's Evaluation. Clin Ophthalmol. 2020;14:171-178. doi:10.2147/OPTH.S234858
Editora
Dove Medical Press